Maytag SDG515DAWW probably over 20 years old. Replaced high limit fuse and thermostat limit. Also replaced the blower fan twice in the past, expect to do it again in the future.

  • partial_accumen@lemmy.world
    link
    fedilink
    English
    arrow-up
    4
    ·
    4 hours ago

    Nice work! Note: If you keep blowing that fuse and thermostat it might indicate your vent is too long/clogged. Ideally you only want perhaps 3 to 4 feet of vent pipe from your dryer to to the wall vent attachment.

    • ThisGuyThat@lemmy.worldOP
      link
      fedilink
      English
      arrow-up
      5
      ·
      4 hours ago

      Thanks for the info. This was a first, think someone overloaded it with two HUGE blankets. The thermostat limit tested fine on multi-meter, but the service manual in bold said “must replace if thermal fuse is replaced”.